Archive 2016 NA CATALOG

Appendix Technical Data Materials

Connectors

PA (Polyamides) Polyamides are high-impact, very tough thermoplastics that exhibit very good electrical insulation characteristics, favorable tracking characteristics, and resistance to flashover. The greater the proportion of filling agents, the lower the water absorption rate and the better the dimensional stability. Their specific surface resistance, due to humidity absorption, is somewhat less than that of other plastics. However, this reduces the likelihood of a build up of electrostatic charge and consequently avoids attracting dust. These characteristics mean that polyamides are suitable for production of casings for electrical plants. Typical applications: high voltage modules, plastic frame grips PC (Polycarbonate) Polycarbonate is an amorphous thermoplastic. It is distinguished by high strength, viscosity, hardness, rigidity, a good resistance to heat and cold in relation to its form, and good electrical characteristics. PC is a glass-clear, easily dyed plastic with very low water absorption, and exhibits high dimensional precision, low waste, and good processability. Typical applications: inserts/ insulators, frames, and individual modules for modular systems PBT (Polybutylenterephthalate) Polybutylenterephthalate is a thermoplastic polyester and is distinguished by its high rigidity, high stability of form under heat, low creep, low water absorption of < 0.2%, high dimensional stability, and good to very good electrical characteristics. It is a tough, viscous plastic with high abrasion resistance, high dimensional stability, and long-term strength combined with good slip and wear characteristics. Typical applications: insert/insulators

Chemical Resistance of Plastics

resistant conditionally resistant not resistant

Diluted acid

PA 6 GF

PA 66 GF

PC GF

PBT GF

Acetone Aqueous ammoniac Benzene Benzol Diesel oil Concentrated acetic acid Alkaline potassium Methanol Engine oil Diluted alkalis Chlorohydrocarbons Outdoor exposure Cold water/seawater

Electrical, Thermal & Mechanical Values

Unit

PA 6 GF

PA 66 GF

PC GF

PBT GF

Electrical Values Flash over resistance (DIN 53481; VDE 0303) Tracking current resistance (DIN 53480; VDE 0303) Thermal values Temperature limit for short-term application

Ed * KV/mm 80/40

> 80/40

35

100

CTI

> 500

> 500

> 125 to 250

> 500

°C °C

180 105

200 120

165 130

190 140

Temperature limit for long-term application

Mechanical values Density (DIN 53479)

g/cm3

1.35

1.35

1.34 6000

1.53

Modulus of elasticity in the flexional and tensile test (DIN 53457) Absorption of humidity in NK until occurrence of saturation (DIN 5714)

EZ * MPa 8500/6000 9700/7500

10000

%

2.1

1.5

0.13

0.13

* Numerical information relates to both dry and atmospherically humid conditions

800-774-3539 • www.lappusa.com • www.lappcanada.com • www.lappmexico.com

681