Archived 2016 Lapp Group International Catalog
A7 Selection tables UNITRONIC ® BUS and ETHERLINE ® – technical data
1096 ÖLFLEX ® ACCESSORIES FLEXIMARK ® SILVYN ® SKINTOP ® EPIC ® HITRONIC ® ETHERLINE ® UNITRONIC ® APPENDIX flexing flexing
Usage criteria
Cable designation
Page 372
374
373
323
324
329
338 340
334
356
359
359
369
369
360
328
highly flexible application (0.25 mm 2 ) UNITRONIC ® BUS FF 3 ARM fixed installation UNITRONIC ® BUS FF 2 fixed installation UNITRONIC ® BUS CAN TRAY
fixed installation (0.22 mm 2 ) UNITRONIC ® BUS FD P CAN FD P
UNITRONIC ® BUS IBS
UNITRONIC ® BUS IBS FD P
highly flexible application UNITRONIC ® BUS IBS Yv
suitable for outdoor use/direct burial UNITRONIC ® BUS LD fixed installation UNITRONIC ® BUS LD FD P
highly flexible application UNITRONIC ® BUS PB fixed installation
UNITRONIC ® BUS PB FD P + PB FD P FC highly flexible application UNITRONIC ® BUS PB Yv
suitable for outdoor use/direct burial UNITRONIC ® BUS PA (blue + black) fixed installation UNITRONIC ® BUS CAN
UNITRONIC ® BUS PB TRAY
fixed installation
Parameter Characteristic impedance Ω
100– 120
150 +/-15
150 +/-15
150 +/-15
100 +/-20 120 120 100 100 120 150 +/-15
100 100 100 100– 120
Mutual capacitance (800 Hz) max. nF/km
60 60 60 60 60 30 30 30 52 40 40 56 65 40 30
Peak operating voltage V (not for power applications)
250 250 250 250 250 250 250 250 250 250 250 300 300 250 250
Test voltage, core/core, U eff V
1500 1500 1500 1500 1500 1500 1500 1500 1500 1500 1500 1500 1500 2000 2000
Conductor resistance (loop) Data network cable pair max. Ω/km
186 159.8 186 186 159.8 110 145,
133 115 44 186 159.8 ≤ 24 ≤ 24 110.8 110
Minimum bending radius, fixed installation
8 x D – 8 x D 8 x D – 75 mm – 75 mm 65 mm 8 x D – 15 x D 15 x D 8 x D 8 x D
Minimum bending radius, flexing
– 15 x D –
– 15 x D –
**
–
–
– 15 x D –
–
–
–
Temperature range fixed installation
from °C
- 30 +80
- 40 +80
- 40 +70
- 40 +80
- 40 +80 - 30 +70
- 40 +80
- 40 +80
- 40 +80
- 30 +80
- 30 +80
- 40 +80 - 30 +70
- 25 +80
- 25 +105
- 40 +80
- 40 +80 - 10 +70
to °C
Temperature range
from °C
– - 5 +70
– - 30 +70
–
– - 5 +70
–
– - 10 +70
to °C – - 30 +70
Usage criteria
Cable designation
Page 370
370
412
412
412
412
413
413
416
416
417
419
419
421
UNITRONIC ® BUS CC
UNITRONIC ® BUS CC FD P FRNC
highly flexible application ETHERLINE ® H Cat.5e fixed installation ETHERLINE ® P Cat.5e
fixed installation ETHERLINE ® H-H Cat.5e
ETHERLINE ® H FLEX Cat.5e
flexible application ETHERLINE ® P FLEX
ETHERLINE ® Y FLEX Cat.5e
ETHERLINE ® Y EC FLEX Cat.5e
ETHERLINE ® P EC FLEX Cat.5e
ETHERLINE ® P EC FD Cat.5e
ETHERLINE ® PN Cat.5 Y FLEX FC
ETHERLINE ® PN Cat.5 FRNC FLEX FC ETHERLINE ® TORSION Cat.5
fixed installation
fixed installation
flexible application
Parameter Characteristic impedance Ω
110 110 100 100 100 100 100 100 100 100 100 100 100 100
Mutual capacitance (800 Hz) max. nF/km
60 60 48 46 46 48 48 –
–
–
–
–
–
–
Peak operating voltage V (not for power applications)
300 300 125 125 125 125 125 125 100 100 100 125 125 100
Test voltage, core/core, U eff V
2000 2000 1000 1000 1000 1000 1000 1000 1000 1000 1000 2000 2000 700
Conductor resistance (loop) Data network cable pair max. Ω/km
37.8 37.8 192 186.6 186.6 284 284 –
–
–
–
–
–
–
Minimum bending radius, fixed installation
15 x D 4 x D 7.5-8 x D 7.5-8 x D 8 x D 8 x D 8 x D 8 x D 4 x D 4 x D 4 x D 10 x D 4 x D 5 x D
Minimum bending radius, flexing
– 8 x D –
–
– 15 x D 15 x D 15 x D 8 x D 8 x D 8 x D 15 x D 8 x D 5 x D
Temperature range fixed installation
from °C
- 40 +70
- 40 +80
- 30 +80 - 5 +60
- 30 +80 - 5 +60
- 30 +80 - 5 +60
- 30 +80 - 5 +60
- 30 +80 - 5 +60
- 40 +80 - 10 +70
- 30 +80 - 5 +50
- 40 +80 - 30 +50
- 40 +80 - 30 +50
- 40 +80 - 20 +60
- 25 +80 - 25 +80
- 40 +80 - 40 +80
to °C
Temperature range
from °C
to °C – - 40 +80
**without FC = 65 mm/FC = 120 mm
For current information see: www.lappgroup.com
Made with FlippingBook - professional solution for displaying marketing and sales documents online