T8 Technical Tables Extension and compensating cables - colour codes and background information
1120 ÖLFLEX ® ACCESSORIES FLEXIMARK ® SILVYN ® SKINTOP ® EPIC ® HITRONIC ® ETHERLINE ® UNITRONIC ® APPENDIX T U J L E K N R S B
Table 8-1: international colour codes for extension and compensating cables
Thermo couple
DIN 43710*
BS 4937
IEC 60584-3
NF C 42-324
ANSI MC 96.1
Designation
Designation
Designation
Designation
Designation
Material
XC
CC
XC
CC
XC
CC
XC
CC
XC
CC
TX
TX
TX
TX
Cu – CuNi
-25°C up to +100°C
0°C up to +100°C
0°C up to +100°C
-25°C up to +100°C
UX
Cu – CuNi
0°C up to +200°C
JX
JX
JX
JX
Fe – CuNi
-25°C up to +200°C
0°C up to +200°C
0°C up to +200°C
-25°C up to +200°C
LX
Fe – CuNi
0°C up to +200°C
EX
EX
EX
EX
NiCr – CuNi
-25°C up to +200°C
0°C up to +200°C
0°C up to +200°C
-25°C up to +200°C
KX
KX
KX
KX
KX
NiCr – Ni
-25°C up to +200°C
0°C up to +200°C
0°C up to +200°C
0°C up to +200°C
-25°C up to +200°C
KCA
WC
KCA
NiCr – Ni
0°C up to +150°C
0°C up to +150°C
0°C up to +150°C
VX
VC
KCB
NiCr – Ni
0°C up to +100°C
0°C up to +100°C
0°C up to +100°C
NX
NC
NiCrSi – NiSi
-25°C up to 0°C up to +200°C +150°C
PtRh13 – Pt PtRh10 – Pt
RCB SCB
RCB SCB
SX
SX
SC
0°C up to +200°C
0°C up to +200°C
0°C up to +200°C
0°C up to +200°C
0°C up to +200°C
BX
BC
PtRh30 – PtRh6
0°C up to +100°C
0°C up to +100°C
The stated temperature specifies the application temperature range for each type. The application temperature range must be reduced if it is required by the insulation material used for the cable. *DIN 43710 was withdrawn in April 1994.
XC = extension cables CC = compensating cables
For current information see: www.lappgroup.com