LAPP North America's current product catalog
Appendix Technical data
Laboratory Laboratory services
The LAPP North America Laboratory (NAL) offers a unique and exclusive service for our customers: the ability to validate available products in the market, authenticate test methods and procedures in accordance to UL standards, and simulate product performance in field applications.
Together, the North American Laboratory staff members’ experience totals over 50 years in the wire and cable industry. LAPP NAL is fully capable to simulate test conditions similar to real world mechanical, electrical, environmental and motion applications.
Using the test services offered by LAPP NAL will pay off with huge dividends by saving time and money. Customers can now rest assured with the knowledge that a product’s test performance is no longer in question. This commitment is clearly reflected in LAPP’s current product portfolio and offerings.
The LAPP North America Laboratory has the capability to perform a wide variety of mechanical, electrical, environmental, and motion testing:
Conditions
Types of test
Test method
Oil resistance I
unaged sample is submerged in oils or chemicals in a controlled environment to be tested for physical properties retention
High temperature
Oil resistance II
Air oven aging
unaged sample in a controlled environment to be tested for physical properties retention
Cold impact
sample prepared at required low temperature to be tested for impact
Low temperature
Cold bend
sample prepared at required low temperature and wrapped around a mandrel
Tensile & elongation
tubular or dumbbell samples to be tested for tensile strength & elongation
Exposed run crush
crushes made on a sample with a gradual compression force
Mechanical
Exposed run impact
impacts on sample with a free-fall force
Direct burial
crushes on a sample with constant compression force for 60 seconds
Abrasion
samples for abrasion resistance are secured by weight force and rubbed against using emery cloth
Direct current resistance
maximum DC resistance is measured across a conductor sample
Electrical
Short term insulation resistance
sample is submerged in water for a short period in a controlled environment to be tested for insulation resistance
Vertical flame
Flame
flame application for applicable duration, sample must self-extinguish
Horizontal flame
Continuous flexing
sample is tested for flexibility based on bend radius and speed
Motion
Torsion
sample is tested for torsion based on twist angle
Terms and conditions 1.
A complete detailed test report will be provided. Test data is intended for reference purposes only.
2.
3. For prices and details, please contact nalg@lappusa.com.
for current information see: www.lappusa.com • www.lappcanada.com
647
Made with FlippingBook flipbook maker