LAPP North America's current product catalog

ÖLFLEX ® Flexible cable for drives, motors & assemblies

VFD cable

Flexible VFD cable; 600V/1000V; c(UL) CIC/TC-ER approval ÖLFLEX ® VFD 1XLC with Signal

Construction

Conductors: tinned copper fine wire Insulation: XLPE (plus)

LAPP KABEL

ÖLFLEX ® VFD 1XLC with Signal

ÖLFLEX ® VFD 1XLC with Signal is designed to meet Canadian standards. A robust oil- and UV-resistant shielded motor cable for VFD drives. c(UL) CIC/TC-ER rating allows for installation in exposed areas without conduit where TECK 90 cables can be used. Enhanced electrical properties of XLPE insulation provide problem free performance where precision control is critical.

• O ne cable for applications • Low capacitance design • c (UL) CIC TC-ER approved • Industrial grade phthalate-free jacket design for harsh environments •R educes space and weight in tray • No conduit required due to TC-ER rating • Resistant to a wide range of disinfecting solutions used in the food, beverage, chemical and related industries, according to ECOLAB ® PM 40-1 test procedure Signal Pair: individually foil shielded with TC drain wire Jacket: specially formulated thermoplastic elastomer (TPE); black Application advantage Shielding: barrier tape; triple layer foil tape (100% coverage); tinned copper braid (85% coverage); tinned copper drain wire

Recommended applications

VFD drive and motor connections; pumps; compressors; conveyors; elevators; extruders; presses; HVAC; on/off, slow down/speed up applications.

Approvals

FIRE PROTECTION

Cable attributes

page 648

Complete the installation SKINTOP ® MS-M BRUSH page 524

OR-03

FR-03

OIL

FLAME

EPIC ® ULTRA HB page 407

MOTION FL-02

MP-03

MECH.

Technical data Minimum bend radius: for installation: Temperature range: - UL/CSA: - for stationary use:

Color code:

b lack with white numbers, plus green/yellow ground 1-pair: b lack with white numbers

7.5 x OD

Approvals:

-25°C to +90°C -40°C to +90°C -25°C to +90°C

Canda: c(UL) CIC/TC-ER

cRU AWM II A/B FT4 UL: TC-ER per UL 1277

- for flexible use:

Flexible Motor Supply Cable per UL 2277 AWM 22022 per UL 758

Nominal voltage: - UL TC:

600V

Attributes: UL Oil Res I/II

- UL Flexible Motor Supply:

1000V 1000V

XHHW-2 90°C wet or dry -40°C cold bend; -25°C cold impact sunlight resistant direct burial NFPA 79 NEC: C lass 1 Division 2 per NEC Article 501

- UL/CSA AWM:

Test voltage: - 18 AWG - 10 AWG: - 8 AWG - 4 AWG:

3000V 3500V 4000V

- 2 AWG:

Additional: NFPA 79 RoHS II

Conductor stranding: - 16 AWG - 2 AWG

Class K

Number of conductors incl. ground

Nominal outer diameter

Copper weight

Approx. weight

SKINTOP ® MS-SC

SKINTOP ® MS-M BRUSH

Number of conductors incl. ground

Nominal outer diameter

Copper weight

Approx. weight

SKINTOP ® MS-SC

SKINTOP ® MS-M BRUSH

Part number

Part number

in

mm lbs/mft

lbs/mft metric thread metric thread

in

mm lbs/mft

lbs/mft metric thread metric thread

16 AWG (1.3 mm²) 701910 4 + (18 AWG) 0.503 12.8 73.6 137 53112630 53112676 14 AWG (2.1 mm²) 701911 4 + (18 AWG) 0.536 13.6 94.4 166 53112630 53112676 12 AWG (3.3 mm²) 701912 4 + (18 AWG) 0.625 14.8 131.7 210 53112640 53112676 10 AWG (5.3 mm²) 701913 4 + (18 AWG) 0.680 16.6 178.4 289 53112650 53112677

8 AWG (8.5 mm²) 701914 4 + (14 AWG) 0.856 21.7 309.5

448

53112650 53112677

6 AWG (13.5 mm²) 701915 4 + (14 AWG) 1.004 25.5

447.6

694 53112660 53112678

4 AWG (21 mm²) 701916 4 + (14 AWG) 1.125

28.6

649.2 976 53112660 53112678

2 AWG (33.7 mm²) 701917 4 + (14 AWG) 1.281 32.5 1011.2 1483 53112670 53112679

ECOLAB ® is a registered trademark of Ecolab, Inc. Recommended SKINTOP ® assumes minimal OD variance. Additional configurations are available; please see our SKINTOP ® section. If not otherwise specified, all values relating to the product are nominal values. Photographs are not to scale and are not true representations of the products in question.

for current information see: www.lappusa.com • www.lappcanada.com

743

rev. 1 | 5.9.2023

Made with FlippingBook flipbook maker